Companies Profile Products Catalog Enquiry Forms Companies Address Your Feedback Our Clients Email Us




Product Display
Related Links

 

Home 

Magnetic Drive Coupling
 




Construction,Working Principle & Benefits

Technical Specifications

Description
Standard
Optional
M.O.C wetted parts
SS-316
SS-316L, HastelloyB/C, Monel, Inconel, Nickel, titanium etc.
Max. Working Pressure
100 bar (kg/cm2) or 1450 psi
Upto 350 bar (Kg/cm2) or 5000psi. for (a)- (c)
Max. Working temp. with cooling jacket
250 deg.C
Upto 500 deg.C.
Maximum RPM
0-1450 for (a)- (c)
0-500 for (d)- (f)
0-300 for (g)- (h)
Upto 3000 rpm for (a)- (c)
 
Various Models As per Torque Capacity
Sr. No.
Static Torque Capacity
Can be usedFor reactor sizes
End Connections (BSP-Threads)
Model no.
Kg-cm
N.m
lb.in
a)
M20
20
1.96
17.4
50ml-700ml
1 ¼" / ½"
b)
M40
40
3.92
34.7
1, 2 & 5Ltrs.
½"
c)
M80
80
7.85
69.4
10 Ltrs.
½"
d)
M200
200
196
170
20-250Ltrs.
1"-1 ¼"
e)
M400
400
392
340
250-500Ltrs.
1 ¼"-1 ½"
f)
M600
600
59
519
500-1000L
1 ¼"-2"
g)
M1200
1200
118
1039
1000-2000L
1.5"-2.5"
h)
M1600
1600
157
1386
2000-5000L
2.5'

Note: Magnetic drives of higher torque capacity or different shaft diameter & end connections for reactors of any make can be designed on request. Higher torque drives can be used for particular reactor size for viscous liquids