Heating Cooling Circulators

Amar has been leading manufacturer of single fluid heating cooling circulators in India for past many years.

  • Heating circulators with temperature range from ambient to +350°C
  • Heating cooling bath circulators with temperature range from -70°C to +175°C
  • Single fluid closed loop heating cooling circulator with temperature range from -90°C to +250°C
  • Laboratory chillers with temperature range from ambient to -15°C
  • High performance and energy efficient systems
  • Available for reactor volumes from 10 ml to 3000 ltr.
  • Powerful pump for heat transfer fluid circulation
  • High pressure booster pump for flow chemistry
  • Custom made systems for specific applications
  • Accurate & precise temperature control
  • Touch screen models
  • Eco friendly and compact systems
  • Ex-proof systems for hazardous area
  • Application: These system are used for heating & cooling by circulating thermic fluid in metal & glass lined Jacketed / limpet reactors, Glass reactors, Stirred Pressure Autoclave Reactor, Micro reactors, Continuous Flow Reactors, Reaction calorimeters, Rotary evaporators, Heat exchangers, Fermentors etc. in R&D centers, pilot plants & manufacturing facilities of fine & speciality chemicals, bulk drug (API) pharmaceuticals, dyes, intermediates, paints, oils, agrochemical, petrochemicals, oil & gas, chemical research institutes / colleges etc
    • Description: Most chemical processes need precision process temperature control. A heating-cooling circulator is a device that is used to regulate process temperature using thermic fluids or thermic oils. AMAR equipment under the Make in India initiative provides a great import substitute for heating cooling circulators. Being the largest manufacturers of heating cooling systems in India AMAR offers high performance, energy-efficient and powerful systems for a wide temperature range of -90°C to +350°C. These systems incorporate powerful and efficient pumps for thermic fluid circulation. Our systems are suitable for reactor volumes from 100 ml to 3000L. Touch screen models and remote access through PC using SCADA software are also available for ease of operations.
Model CLM-1 CLM-2 CLM-3 CLM-4W
Operating temperature range -30℃ to +200℃
Temperature control accuracy ±0.5℃
Temperature display 4.3" touch screen display 7" touch screen display
Temperature display resolution 0.01
Internal/ jacket temperature sensor 3-wire RTD PT-100 sensor
External/ process sensor required 3-wire RTD PT-100 sensor
Controller type PID, process or jacket control selectable
Communication/ interface RS-485 mod bus, ethernet
Alarm message Indicative
Type of cooling Refrigerated
Refrigerant R-404a, CFC free
@ 0℃ 0.6 kW 0.8 kW 1.2 kW 2.5 kW
@ -20℃ 0.3 kW 0.5 kW 0.7 kW 1.3 kW
@ -30℃ 0.1 kW 0.25 kW 0.3 kW 0.6 kW
Type of heating Electrical
Heating power 1.5 kW 2.5 kW 3.6 kW 4.5 kW
Machine standard version Air-cooled Water-cooled
Cooling water flow minimum NA 250 l/hr
Cooling water pressure NA 3 bar
Cooling water temperature NA 10°C~30°C
Cooling water end connection NA 3⁄4” hose nipple
Circulation pump maximum flow 18~20 l/min 30~35 l/min 40~45 l/min
Circulation pump maximum pressure 0.4 bar 0.7 bar
Machine end connection M16 x 1.5 male M24 x 1.5 male M42 x 1.5 male
Machine overall dimension (W x D x H) 475 x 400 x 800 mm 420 x 520 x 875 mm 450 x 600 x 900 mm 540 x 650 x 1250 mm
MOC Complete SS-304 construction
Power supply 1-phase,230V AC,50Hz 3-phase,420V AC,50Hz
Maximum current 10A 12A 15A
Ambient temperature condition 10°C~30°C 10°C~35°C
Standard safety features  
Phase reversal prevention NA Cut-off, Indication/ message, manual reset
Over temperature protection Cut-off, Indication/ message, auto reset
Compressor over pressure Cut-off, Indication/ message, manual reset
Compressor overheat Cut-off, Indication/ message, auto reset

Note :
Since Development is a continuous process, above specifications can change without prior notice.
The temperature mentioned above is at outlet of the machine hence temperature inside the process/ load may vary due to various factors like process design, distance, head, insulation etc.

Model CLL-1 CLL-2 CLL-3W CLL-4W
Operating temperature range -75°C to +180°C
Temperature control accuracy ±0.5°C
Temperature display 7” touch screen display
Temperature display resolution 0.01
Internal/ jacket temperature sensor 3-wire RTD PT-100 sensor
External/ process sensor required 3-wire RTD PT-100 sensor
Controller type PID, Process or jacket control selectable
Communication/ interface RS-485 mod bus, Ethernet
Alarm message Indicative
Type of cooling Refrigerated
Refrigerant R-404a, CFC free
Cooling power with Methanol
@ 0℃ 0.6kW 1.5kW 2.2kW
@ -40℃ 0.6kW 1.4kW 2.0kW
@ -60℃ 0.3kW 1.2kW 1.4kW
Type of heating Electrical
Heating power 1.5kW 3kW 4.5kW
Machine standard version Air-cooled Water-cooled
Cooling water flow minimum NA 250 l/hr
Cooling water pressure NA 3 bar
Cooling water temperature NA 10°C ~30°C
Cooling water end connection NA 1” hose nipple
Circulation pump maximum flow 30~35 l/min 40~45 l/min
Circulation pump maximum pressure 0.4 bar       0.7 bar
Machine end connection M24 x 1.5 male M42 x 1.5 male
Machine overall dimension (W x D x H) 600 x 650 x 1400 mm 700 x 750 x 1500 mm
MOC Complete SS-304 construction
Power supply 3-phase,420V AC,50Hz
Maximum current 15A 18A 20A
Ambient temperature condition 10°C ~30°C 10°C ~35°C
Standard safety features  
Phase reversal prevention Cut-off, Indication/ message, manual rest
Over temperature protection Cut-off, Indication/Message, Auto reset
Compressor over pressure Cut-off, Indication/ message, manual rest
Compressor overheat Cut-off, Indication/Message, Auto reset

Note :
Since Development is a continuous process, above specifications can change without prior notice.
The temperature mentioned above is at outlet of the machine hence temperature inside the process/ load may vary due to various factors like process design, distance, head, insulation etc.

Model CPM-1W CPM-2W CPM-3W CPM-4W
Operating temperature range -35°C to +200°C -30°C to +200°C
Temperature control accuracy ±0.5°C
Temperature display 7” touch screen display
Temperature display resolution 0.01
Internal/ jacket temperature sensor 3-wire RTD PT-100 sensor
External/ process sensor required 3-wire RTD PT-100 sensor
Controller type PID, Process or jacket control selectable
Communication/ interface RS-485 mod bus, Ethernet
Alarm message Indicative
Type of cooling Refrigerated
Refrigerant R-404a, CFC free
Cooling power with Methanol
@ 0℃ 4 kW 7 kW 12 kW 15 kW
@ -10℃ 2.2 kW 3.5 kW 6 kW 7 kW
@ -30℃ 1.3 kW 1.8 kW 3 kW 3.5 kW
Type of heating Electrical
Heating power 6 kW 9 kW 12 kW 18 kW
Machine standard version Water-cooled
Cooling water flow minimum 400 l/hr 700 l/hr 1200 l/hr 1500 l/hr
Cooling water pressure 3 bar
Cooling water temperature 10°C~30°C
Cooling water end connection 1” hose nipple
Circulation pump maximum flow 50~55 l/min or 80~90 l/min 80~90 l/min
Circulation pump maximum pressure 1.0 bar 1.5 bar
Machine end connection M42 x 1.5 male
Machine overall dimension (W x D x H) 560 x 650 x 1300mm 600 x 690 x 1300mm 700 x 750 x 1500mm 750 x 790 x 1500mm
MOC Complete SS-304 construction
Power supply 3-phase, 420V AC, 50Hz
Maximum current 15A 35A 50A
Ambient temperature condition 10°C~40°C
Phase reversal prevention Cut-off, Indication/Message, Manual reset
Over temperature protection Cut-off, Indication/Message, Auto reset
Compressor over pressure Cut-off, Indication/Message, Manual reset
Compressor over heat Cut-off, Indication/Message, Auto reset

Note :
Since Development is a continuous process, above specifications can change without prior notice.
The temperature mentioned above is at outlet of the machine hence temperature inside the process/ load may vary due to various factors like process design, distance, head, insulation etc.

Model CPL-1W CPL-2W CPL-4W
Operating temperature range -60°C to +200°C
Temperature control accuracy ±0.5°C ±0.01°C
Temperature display 7” touch screen display
Temperature display resolution 0.01
Internal/ jacket temperature sensor 3-wire RTD PT-100 sensor
External/ process sensor required 3-wire RTD PT-100 sensor
Controller type PID, Process or jacket control selectable
Communication/ interface RS-485 mod bus, Ethernet
Alarm message Indicative
Type of cooling Refrigerated
Refrigerant R-404a, CFC free
Cooling power with Methanol
@ 0℃ 6.5kW 12kW 15kW
@ -40℃ 3.2kW 6kW 7kW
@ -60℃ 1kW 1.5kW 2.5kW
Type of heating Electrical
Heating power 6kW 9kW 18kW
Machine standard version Water-cooled
Cooling water flow minimum 650 l/hr 1200 l/hr 1500 l/hr
Cooling water pressure 3 bar
Cooling water temperature 10°C~30°C
Cooling water end connection 1” hose nipple
Circulation pump maximum flow 50~55 l/min 80~90 l/min
Circulation pump maximum pressure 1.0 bar 1.5 bar
Machine end connection M42 x 1.5 male
Machine overall dimension (W x D x H) 750 x 790 x 1500 mm 900 x 950 x 1650 mm
MOC Complete SS-304 construction
Power supply 3-phase, 420V AC, 50Hz
Maximum current 40A 50A 65A
Ambient temperature condition 10°C~40°C
Pump dry run NA Cut-off,Indication/message, auto reset
Phase reversal prevention Cut-off, Indication/message, manual reset
Over temperature protection Cut-off, Indication/message, auto reset
Compressor over pressure Cut-off, Indication/message, manual reset
Compressor overheat Cut-off, Indication/message, auto reset

Note :
Since Development is a continuous process, above specifications can change without prior notice.
The temperature mentioned above is at outlet of the machine hence temperature inside the process/ load may vary due to various factors like process design, distance, head, insulation etc.

Model CHL-1 CHL-2 CHL-3
Operating temperature range Ambient to -15°C
Temperature control accuracy ±2°C
Temperature display LED/LCD
Temperature display resolution 0.1
Temperature sensor 3-wire RTD PT-100 Sensor
Controller type On-Off Control
Alarm message Indicative
Type of cooling Refrigerated
Refrigerant R-404a, CFC Free
Cooling power with Methanol
@ 0℃ 0.35kW 0.7kW 1.2kW
@ -10℃ 0.15kW 0.3kW 0.6kW
Machine standard Version Air-Cooled
Circulation pump maximum pressure 12~14 l/min
Circulation pump Maximum Pressure 0.3 bar 0.5 bar
Machine end connection 3/8” hose nipple 1/2” hose nipple
Machine overall dimension 330 x 370 x 550 mm 360 x 460 x 600 mm 550 x 650 x 700 mm
MOC Body MS powder coated, Media touching part SS-304
Power supply 1-Phase, 230 V AC, 50 Hz
Maximum current 6A 8A 10A
Ambient temperature Condition 10°C~30°C
Standard safety Features:  
Compressor over Pressure Cut-off, Indication, Auto reset
Compressor overheat Cut-off, Indication, Auto reset

Note :
Since Development is a continuous process, above specifications can change without prior notice.
The temperature mentioned above is at outlet of the machine hence temperature inside the process/ load may vary due to various factors like process design, distance, head, insulation etc.

Model CHL-4 CHL-5 CHL-6
Operating temperature range Ambient to -15°C
Temperature control accuracy ±2°C
Temperature display LED/LCD
Temperature display resolution 0.1
Temperature sensor 3-Wire RTD PT-100 sensor
Controller type On-Off Control
Alarm message Indicative
Type of cooling Refrigerated
Refrigerant R-404a, CFC free
Cooling power with Methanol
@ 0℃ 2.4kW 4.5kW 10kW
@ -10℃ 1.5kW 2.5kW 6kW
Machine standard Version Air-Cooled
Circulation pump maximum pressure 30~36 l/min
Circulation pump Maximum Pressure 0.6 bar
Machine end connection 1/2” hose nipple 3/4” hose nipple
Machine overall dimension (W x D x H) 450 x 650 x 1150 mm 700 x 700 x 1200 mm 1300 x 800 x 1600 mm
MOC Body MS powder coated, Media touching SS-304
Power supply 3-Phase, 420 V AC, 50 Hz
Maximum current 6A 8A 25A
Ambient temperature Condition 10°C~30°C
Standard safety Features:  
Compressor over Pressure Cut-off, Indication, Auto Reset
Compressor overheat Cut-off, Indication, Auto Reset

Note :
Since Development is a continuous process, above specifications can change without prior notice.
The temperature mentioned above is at outlet of the machine hence temperature inside the process/ load may vary due to various factors like process design, distance, head, insulation etc.

Model HCL-1 HCL-2 HCL-3
Operating temperature range -70°C to +100°C
Temperature control accuracy ±0.5°C
Temperature display LED/LCD
Temperature display resolution 0.1
Internal/jacket Temperature sensor 3-wire RTD PT-100 sensor
External/ process sensor required 3-wire RTD PT-100 sensor
Controller type PID
Communication/ interface RS-485 mod bus (optional)
Alarm message Indicative
Type of cooling Refrigerated
Refrigerant R-404a, CFC free
Cooling power with Methanol
@ 0℃ 0.4kW 1.1kW 1.5kW
@ -40℃ 0.3kW 0.8kW 1.2kW
@ -60℃ 0.2kW 0.4kW 0.6kW
Type of heating Electrical
Heating power 1kW 2kW 3kW
Machine standard version Air-cooled
Circulation pump maximum flow 14~16 l/min 30~35 l/min
Circulation pump maximum pressure 0.4 bar 0.7 bar
Machine end connection M16 x 1 male M24 x 1.5 male
Machine overall dimension ( W x D x H) 610 x 700 x 1150 mm 700 x 700 x 1300 mm
MOC Complete SS-304 construction
Power supply 1-phase, 230V AC, 50 Hz 3-phase,420V AC, 50 Hz
Maximum current 15A 20A 15A
Ambient temperature condition 10°C~35°C
Standard safety features  
Oil level in bath Cut-off, Indication/message, Auto reset
Phase reversal prevention NA Cut-off, Indication/message, manual reset
Over temperature protection Cut-off, Indication/message, Auto reset
Compressor over pressure Cut-off, Indication/message, manual reset
Compressor overheat Cut-off, Indication/message, Auto reset

Note :
Since Development is a continuous process, above specifications can change without prior notice.
The temperature mentioned above is at outlet of the machine hence temperature inside the process/ load may vary due to various factors like process design, distance, head, insulation etc.

Model HCB-1 HCB-2 HCB-3
Operating temperature range -25°C to + 175°C
Temperature control accuracy ±0.5°C
Temperature display LED/LCD
Temperature display resolution 0.1
Internal/jacket Temperature sensor 3-wire RTD PT-100 Sensor
External/ process sensor required 3-wire RTD PT-100 sensor
Controller type PID
Communication/ interface RS-485 mod bus (optional)
Alarm message Indicative
Type of cooling Refrigerated
Refrigerant R-404a, CFC free
Cooling power with Methanol
@ 0℃ 0.4kW 1.1kW 1.5kW
@ -10℃ 0.2kW 0.7kW 1kW
@ -25℃ 0.05kW 0.3kW 0.45kW
Type of heating Electrical
Heating power 1kW 2kW 3kW
Machine standard version Air-cooled
Circulation pump maximum flow 14~16 l/min 30~35 l/min
Circulation pump maximum pressure 0.4 bar 0.7 bar
Machine end connection M16 x 1 male M16 x 1.5 male M24 x 1.5 male
Machine overall dimension (W x D x H) 300 x 500 x 710 mm 420 x 520 x 1000 mm 510 x 620 x 1050 mm
MOC Complete SS-304 construction
Power supply 1-phase, 230V AC, 50 Hz 3-phase, 420V AC, 50Hz
Maximum current 8A 12A 8A
Ambient temperature condition 10°C~35°C
Standard safety features  
Oil level in bath Cut-off, Indication/message, auto reset
Over temperature protection Cut-off, Indication/message, auto reset
Phase reversal prevention NA Cut-off, Indication/message, manual reset
Compressor over pressure Cut-off, Indication/message, manual reset
Compressor overheat Cut-off, Indication/message, auto reset

Note :
Since Development is a continuous process, above specifications can change without prior notice.
The temperature mentioned above is at outlet of the machine hence temperature inside the process/ load may vary due to various factors like process design, distance, head, insulation etc.

Model HB-1 HB-2 HB-3
Operating temperature range Ambient to +200°C
Temperature control accuracy ±0.5°C
Temperature display LED/LCD
Temperature display resolution 0.1
Internal/jacket Temperature sensor 3-wire RTD PT-100 sensor
External/ process sensor required 3-wire RTD PT-100 sensor
Controller type PID
Communication/ interface RS-485 mod bus (optional)
Alarm message Indicative
Type of cooling Through internal cooling coil. Provision of internal cooling to bring machine temperature to ambient by circulation external cooling water through it.
Cooling coil end connections 3/8” BSP male
Type of heating Electrical
Heating power 1kW 2kW 3kW
Machine standard Version Air-cooled
Circulation pump Maximum Flow 14~16 l/min 30~35 l/min
Circulation pump Maximum Pressure 0.4 bar 0.7 bar
Machine end connection M16 x 1 male M24 x 1.5 male
Machine overall dimension (W x D x H) 300 x 500 x 450 mm 430 x 560 x 550 mm 510 x 620 x 600 mm
MOC Complete SS-304 construction
Power supply 1-phase, 230V AC, 50 Hz 3-phase, 420V AC, 5Hz
Maximum current 6A 10A 8A
Ambient temperature condition 10°C~35°C
Standard safety Features:  
Oil level low in bath Cut-off, Indication/ message, auto reset
Phase reversal prevention NA Cut-off, Indication/Message, manual reset
Over temperature Protection Cut-off, indication/ message, auto reset

Note :
Since Development is a continuous process, above specifications can change without prior notice.
The temperature mentioned above is at outlet of the machine hence temperature inside the process/ load may vary due to various factors like process design, distance, head, insulationv etc.

Model HTC-1 HTC-2 HTC-3
Operating temperature range Ambient to +350°C
Temperature control accuracy ±0.5°C
Temperature display LED/LCD 4.3” touch screen display
Temperature display resolution 0.1 0.01
Internal/jacket Temperature sensor 3-wire RTD PT-100 sensor
External/ process sensor required 3-wire RTD PT-100 sensor
Controller type PID
Communication/ interface RS-485 mod bus (optional)
Alarm message Indicative
Type of cooling Through internal cooling coil. Provision of internal cooling coil to bring machine temperature to ambient by circulation external cooling water through it.
Cooling coil end connections 3/8” BSP male
Type of heating Electrical
Heating power 3kW 6kW 12kW
Machine standard Version Air-cooled
Circulation pump Maximum Flow 30~35 l/min 50~55 l/min
Circulation pump Maximum Pressure 0.7 bar
Machine end connection M24 x 1.5 male
Machine overall dimension (W x D x H) 410 x 410 x 700 mm 600 x 600 x 900 mm 900 x 900 x 1100 mm
Control panel overall dimension (W x D x H) 300 x 300 x 300 mm
MOC Complete SS-304 construction
Power supply 1-phase, 230V AC, 50Hz 3-phase,420V AC, 50Hz
Maximum current 18A 12A 22A
Ambient temperature condition 10°C~35°C
Standard safety features :  
Over pressure protection Cut-off Indication, auto reset

Note :
Since Development is a continuous process, above specifications can change without prior notice.
The temperature mentioned above is at outlet of the machine hence temperature inside the process/ load may vary due to various factors like process design, distance, head, insulation etc.

Accessories

Apart from our standard specifications we also provide additional value-added optional accessories to enhance the versatility and functionality of the equipment for various applications.

  • Silicon Heat transfer Fluid: Synthetic/silicon heat transfer fluid for wide temperature range (nontoxic & nonflammable)
  • SCADA Software: SCADA software for PC operated / programmable heating or cooling machines with online & historical data Logging
  • SS Hose pipe: Flexible SS hose pipes with insulation for fluid circulation
  • Purge Panel: Purge panel for complete unit to use in Ex-proof area
  • Flameproof Panel: Flame proof panel for remote set point

Note : All accessories may not be applicable for the selected model. For more details Contact US.

  • PDFGeneral Catalog
  • PDFHeating Bath
  • PDFHeating Cooling Bath
  • PDFHeating Cooling Cryo Bath
  • PDFLaboratory Chiller
  • PDFSingle Fluid Closed Loop Circulators
  • PDFHeating Cooling Circulator Catalog
Enquire Now