Home About Us Products Catalogue Clients Technicals Inquiry Contact Us Sitemap

Special Autoclaves

Interchangeable Glass & Metal Autoclave
Multiple Autoclave System
Continuous flow stirred tank reactors (CSTR)
Interchangeable Metal Autoclaves
Acid Digestion Bombs
Oxygen Combustion Bombs
Compact Autoclaves
 

» Interchangeable Glass & Metal Autoclave
Interchangeable glass cylinder assembly with top bottom SS flanges, external bottom plate heater, pressure safety valve & safety shield to fit in a existing Standard SS Autoclave for sizes from 100 ml to 2 Ltrs. i.e. all common fittings except body of SS 316 and Glass Interchangeable for same capacity. Optionally wetted parts of PTFE Coated SS 316 can be offered. It is highly economical, compact & versatile.

For Glass Body
For SS Body
Max. Working Pressure (kg/cm2)
6
100
Max. Working Temperature (deg C.)
150
250
Multiple pressure autoclaves, Multiple lab pressure autoclaves, Multiple high pressure lab autoclaves, Multiple stirred pressure autoclaves, Multiple stirred high pressure autoclaves, Stirred Reactors, High pressure stirred reactors, High pressure lab stirred reactors, High temperature stirred reactors, High temperature lab stirred reactors, Laboratory  Stirred reactors, Laboratory  high pressure stirred reactors


» Multiple Autoclave System

4 or 6 parellel reactors can be offered on the same mounting with common control panel with complete data acquisition on PC and optionally individual gas mass flow controllers to control and indicate the gas consumed. The system can have all reactors of same size or different sizes. Simultaneous reactions can be carried on each reactor with diffrent parameters and comparative studies can be done from the data received. It saves lot of space and helps in advanced and faster research .i.e. high throughput testing.

Salient Features:

• 50ml to 700ml, parallel 4 or 6 autoclaves can be offered with bottom magnetic stirrer to make it compact & economical.
• Common HMI / Touch screen to monitor all the parameters of all autoclaves on single screen.
• Very compact panels with SLACM cards / PLC.

Multiple pressure autoclaves, Multiple lab pressure autoclaves, Multiple high pressure lab autoclaves, Multiple stirred pressure autoclaves, Multiple stirred high pressure autoclaves, Stirred Reactors, High pressure stirred reactors, High pressure lab stirred reactors, High temperature stirred reactors, High temperature lab stirred reactors, Laboratory  Stirred reactors, Laboratory  high pressure stirred reactors

Multiple pressure autoclaves, Multiple lab pressure autoclaves, Multiple high pressure lab autoclaves, Multiple stirred pressure autoclaves, Multiple stirred high pressure autoclaves, Stirred Reactors, High pressure stirred reactors, High pressure lab stirred reactors, High temperature stirred reactors, High temperature lab stirred reactors, Laboratory  Stirred reactors, Laboratory  high pressure stirred reactors


» Continuous flow stirred tank reactors (CSTR)
These are used for reactions in which reactants are to be introduced & products to be removed on continuous basis at high pressure & temperatures. These type of reactors are custom built with multiple inlets & outlets with automatic metering pump system, gas flow controllers, back pressure regulators, auto sampling systems etc.


» Interchangeable Metal Autoclaves

Autoclaves with common head, external fittings, panel, motor, trolley etc. & interchangeable separate 2nos. vessel, heater & internal fittings (possible for 400ml, 700ml, 1Ltr. & 2Ltrs autoclaves). Amar does not promote this option as this is possible in autoclave having same diameter. Only the heights being different the minimum Stirrable volume is same hence it is advisable to go for only higher volume autoclave as changing the internal fittings like cooling coil & thermowell is not advisable regularly (if not refitted properly user many face leakage problem).Interchangeable any 2 autoclaves with common panel, motor & trolley. If space is the constraint, cost of panel, motor & trolley of one autoclave can be saved but the user loses the flexibility of using 2 autoclaves at a time. This option is possible for 50ml-5Ltrs., any two size autoclaves at a time.

Multiple pressure autoclaves, Multiple lab pressure autoclaves, Multiple high pressure lab autoclaves, Multiple stirred pressure autoclaves, Multiple stirred high pressure autoclaves, Stirred Reactors, High pressure stirred reactors, High pressure lab stirred reactors, High temperature stirred reactors, High temperature lab stirred reactors, Laboratory  Stirred reactors, Laboratory  high pressure stirred reactors


» Acid Digestion Bombs
They are used for dissolving or digesting inorganic or organic samples in strong acids or alkalis in chemically resistant PTFE-lined vessels at high temperature & pressures with complete containment & recovery.

Sizes
25ml to 200ml
Max. Working Pressure
1500psi, optional Up to 5000 PSI
Multiple pressure autoclaves, Multiple lab pressure autoclaves, Multiple high pressure lab autoclaves, Multiple stirred pressure autoclaves, Multiple stirred high pressure autoclaves, Stirred Reactors, High pressure stirred reactors, High pressure lab stirred reactors, High temperature stirred reactors, High temperature lab stirred reactors, Laboratory  Stirred reactors, Laboratory  high pressure stirred reactors


» Oxygen Combustion Bombs
They are used for converting solid or liquid combustible samples into water soluble forms, rapidly & completely by combustion with oxygen in properly designed combustion bombs.

Sizes
25ml to 2Ltrs.
Max. Working Pressure
Up to 3000 PSI
Multiple pressure autoclaves, Multiple lab pressure autoclaves, Multiple high pressure lab autoclaves, Multiple stirred pressure autoclaves, Multiple stirred high pressure autoclaves, Stirred Reactors, High pressure stirred reactors, High pressure lab stirred reactors, High temperature stirred reactors, High temperature lab stirred reactors, Laboratory  Stirred reactors, Laboratory  high pressure stirred reactors


» Compact Autoclaves
• Magnetic drive with integral mini brushless DC motor in common enclosure.

• Available in 50ml-2ltrs. Size.

• Very compact & hence occupies very less table space.

• Motor coupling, mounting, stand eliminated & hence no alignment, vibrations & noise problem.

• All other specifications as per stirred autoclaves.

Multiple pressure autoclaves, Multiple lab pressure autoclaves, Multiple high pressure lab autoclaves, Multiple stirred pressure autoclaves, Multiple stirred high pressure autoclaves, Stirred Reactors, High pressure stirred reactors, High pressure lab stirred reactors, High temperature stirred reactors, High temperature lab stirred reactors, Laboratory  Stirred reactors, Laboratory  high pressure stirred reactors