| Heating & Cooling Baths with Circulator |
| |
 |
| |
| Salient Features : |
| » |
Cooling baths with temperature upto -70°C |
| » |
Heating Baths with temperature upto 250°C |
| » |
Heating & cooling in common bath for - 70 to 250°C |
| » |
Closed loop systems to use single fluid for entire range |
| » |
No fuming of thermic fluid in closed loop systems |
| » |
Compact, eco frindly & energy efficient system |
| » |
Accurate temperature control |
| » |
PC operated / programmable system |
| » |
Suitable for reactor sizes from 1ltr. to 500 ltrs. |
| » |
Air cooled & water cooled machines |
|
| |
| Technical Specifications : |
| Temperature Controller |
: |
PID for all except Eco series will have ±1.5°C |
| Display Resolution |
: |
0.1°C |
| Controller Accuracy |
: |
±0.5°C for all except Eco series will have ±1.5°C |
| M.O.C. |
: |
Bath, Bath Lid, Pump & all medium touched parts SS304 & body shall be MS powder coated for all except closed loop systems shall have complete SS construction |
| Safety interlocks for low level, high temperature, pump flow & compresssor overload etc. |
|
| |
| Heating Bath Circulator |
Temperature range : 35°C to + 200°C & -20°C to +200°C with internal coil.
| Model No. |
HB-21 |
HB-22 |
HB-23 |
| Bath Volume (Ltr.) |
4˜6 |
20 |
20 |
| Bath Opening (mm) |
100 x 100 |
150 x 100 |
150 x 100 |
| Heating Capacity (kW) |
1.50 |
3.00 |
6.00 |
| Pump Flow (LPM) |
14˜20 |
14˜20 |
14˜20 |
| Max. Pump Pressure (bar) |
0.5 |
0.5 |
0.5 |
| Overall Dimentions in mm (WxDxH) |
300 x 425 x 650 |
350 x 500 x 755 |
450 x 500 x 755 |
| Power Supply |
220V 50Hz 1Ph |
440V 50Hz 3Ph |
440V 50Hz 3Ph |
| Total Load (kW) |
2 |
4 |
7.5 |
|
| |
| Lab.Cooling Bath Circulator - Eco Series |
Temperature range : -20°C to Ambient
| Model No. |
CB-21 |
CB-22 |
CB-23 |
CB-24 |
CB-25 |
CB-26 |
| Bath Volume (Ltr.) |
4˜6 |
4˜6 |
4˜6 |
8˜10 |
20 |
20 |
| Bath Opening (mm) |
100 x 100 |
100 x 100 |
100 x 100 |
150 x 100 |
150 x 100 |
150 x 100 |
Cooling Power
@ +20°C (kW)
@ 0°C (kW)
@ -20°C (kW) |
0.20
0.10
0.05 |
0.27
0.15
0.06 |
0.50
0.32
0.15 |
0.90
0.50
0.23 |
3.00
1.50
0.71 |
4.00
3.15
1.44 |
| Pump Flow (LPM) |
14˜20 |
14˜20 |
14˜20 |
14˜20 |
30˜35 |
30˜35 |
| Max. Pump Pressure (bar) |
0.5 |
0.5 |
0.5 |
0.5 |
0.7 |
0.7 |
| Overall Dimentions in mm (WxDxH) |
300 x 425 x 650 |
300 x 425 x 650 |
300 x 425 x 650 |
300 x 425 x 650 |
450 x 500 x 755 |
450 x 500 x 755 |
| Power Supply |
220V 50Hz 1Ph |
220V 50Hz 1Ph |
220V 50Hz 1Ph |
220V 50Hz 1Ph |
440V 50Hz 3Ph |
440V 50Hz 3Ph |
| Total Load (kW) |
2.1 |
2.25 |
2.5 |
2.7 |
7.5 |
9.2 |
|
| |
| Lab. Heating / Cooling Bath Circulator |
(a) Temperature range : -20°C to +200°C
| Model No. |
HCB-221 |
HCB-222 |
HCB-223 |
HCB-224 |
HCB-225 |
HCB-226 |
| Bath Volume (Ltr.) |
4˜6 |
4˜6 |
4˜6 |
8˜10 |
20 |
20 |
| Bath Opening (mm) |
100 x 100 |
100 x 100 |
100 x 100 |
150 x 100 |
150 x 100 |
150 x 100 |
| Heating Capacity (kW) |
1.50 |
1.50 |
1.50 |
1.50 |
3.00 |
3.00 |
Cooling Power
@ +20°C (kW)
@ 0°C (kW)
@ -20°C (kW) |
0.20
0.10
0.05 |
0.27
0.15
0.06 |
0.50
0.32
0.15 |
0.90
0.50
0.23 |
3.00
1.50
0.71 |
4.00
3.15
1.44 |
| Pump Flow (LPM) |
14˜20 |
14˜20 |
14˜20 |
14˜20 |
30˜35 |
30˜35 |
| Max. Pump Pressure (bar) |
0.5 |
0.5 |
0.5 |
0.5 |
0.7 |
0.7 |
| Overall Dimentions in mm (WxDxH) |
300 x 425 x 650 |
300 x 425 x 650 |
300 x 425 x 650 |
300 x 425 x 650 |
450 x 500 x 755 |
450 x 500 x 755 |
| Power Supply |
220V 50Hz 1Ph |
220V 50Hz 1Ph |
220V 50Hz 1Ph |
220V 50Hz 1Ph |
440V 50Hz 3Ph |
440V 50Hz 3Ph |
| Total Load (kW) |
2.1 |
2.25 |
2.5 |
2.7 |
7.5 |
9.2 |
|
| |
(b) Temperature range : -30°C to 200°C
| Model No. |
HCB-321 |
HCB-322 |
HCB-323 |
HCB-324 |
HCB-325 |
HCB-326 |
| Bath Volume (Ltr.) |
4˜6 |
4˜6 |
4˜6 |
8˜10 |
20 |
20 |
| Bath Opening (mm) |
100 x 100 |
100 x 100 |
100 x 100 |
150 x 100 |
150 x 100 |
150 x 100 |
| Heating Capacity (kW) |
2.00 |
2.00 |
2.00 |
2.00 |
2.00 |
3.00 |
Cooling Power
@ +20°C (kW)
@ 0°C (kW)
@ -20°C (kW)
@ -30°C (kW) |
0.90
0.60
0.20
0.10 |
1.00
0.77
0.35
0.15 |
1.20
1.00
0.45
0.20 |
1.50
1.20
0.50
0.25 |
2.00
1.55
0.71
0.29 |
4.00
3.15
1.44
0.60 |
| Pump Flow (LPM) |
14˜20 |
14˜20 |
14˜20 |
30˜35 |
30˜40 |
30˜40 |
| Max. Pump Pressure (bar) |
0.5 |
0.5 |
0.5 |
0.7 |
0.7 |
0.7 |
| Overall Dimentions in mm (WxDxH) |
300 x 425 x 650 |
300 x 425 x 650 |
300 x 425 x 650 |
450 x 500 x 755 |
450 x 500 x 755 |
450 x 500 x 755 |
| Power Supply |
220V 50Hz 1Ph |
220V 50Hz 1Ph |
220V 50Hz 1Ph |
220V 50Hz 1Ph |
440V 50Hz 3Ph |
440V 50Hz 3Ph |
| Total Load (kW) |
3.3 |
3.4 |
3.5 |
3.6 |
3.75 |
10 |
|
| |
(c) Temperature range : -70°C to 100°C
| Machine Model |
HCB-711 |
HCB-712 |
| Bath Volume (Ltr.) |
15-20 |
15-20 |
| Bath Opening (mm) |
100 x 100 |
100 x 100 |
| Heating Capacity (kW) |
1.50 |
1.50 |
Cooling Power
@ +20°C (kW)
@ 0°C (kW)
@ -20°C (kW)
@ -40°C (kW)
@-60°C (kW) |
1.1
1.1
1.0
0.8
0.5 |
1.5
1.5
1.2
1.2
0.8 |
| Pump Flow (LPM) |
14˜20 |
14˜20 |
| Max. Pump Pressure (bar) |
0.7 bar Max |
0.7 bar Max |
| Overall Dimentions in mm (WxDxH) |
600 x 650 x 950 |
600 x 650 x 950 |
| Power Supply |
220V 50Hz 1Ph |
220V 50Hz 1Ph |
| Max Power (kW) |
4.5 |
5.5 |
|
| |
| Single fluid heating / Cooling Closed Loop System |
| Model No. |
Temperature Range |
Heating Power kW |
Cooling power kW |
Pump Flow LPM |
| @ 0°C |
@ -20°C |
@ -30°C |
| CLS-321 |
-35 to 200°C |
1.5 |
1.2 |
0.6 |
0.3 |
30 |
| CLS-322 |
-35 to 200°C |
3 |
2.5 |
1.2 |
0.5 |
45 |
| CLS-323 |
-35 to 200°C |
3 |
3.3 |
1.8 |
0.9 |
45 |
| CLS-324 |
-35 to 200°C |
4.5 |
4.5 |
2.5 |
1.2 |
55 |
| CLS-325 |
-35 to 200°C |
6 |
5.5 |
3.0 |
1.5 |
55 |
| CLS-326 |
-35 to 200°C |
9 |
6.6 |
4.0 |
1.8 |
60 |
| CLS-327 |
-35 to 200°C |
18 |
9.0 |
6.0 |
3.0 |
80 |
| CLS-328 |
-35 to 200°C |
24 |
20.0 |
13.0 |
7.0 |
80 |
| CLS-621 |
-60 to 200°C |
6 |
6 |
5 |
2.8 |
60 |
| CLS-622 |
-60 to 200°C |
9 |
9 |
8 |
4.5 |
100 |
Max.pump pressure 1.5 bar for all the models & same can be high on request |
| Optional Accessories |
| » |
Synthetic thermic/silicon fluid (non toxic & non flammable) for heating & cooling for tempretures from -70°C to +200°C |
| » |
Flexible SS hose pipes with insulation for fluid circulation |
| » |
PC operated/programmable heating or cooling bath with online & historical data logging |
| » |
Extermal process tempreture control |
|
| |
| Applications |
| Used for rotavapours, SS/ Glass reactor (micro, lab & plant scale) , heat exchanger, fermentors etc. in laboratories/pilot plant of all Pharmaceuticals, Chemicals, Beverage, Paint, Dye, Petrochemical, Agrochemical etc. Industries & in research & educational institutes. |
| |
 |
| Top |
|